A Rinnai continuous flow error code is the unit telling you why it shut down. Code 11 means it couldn't ignite, usually because the gas is off or the LPG bottle is empty. Code 12 means the flame went out, often for the same reason or a blocked flue. Most other codes, such as 10, 14, 16, 52, 61 and 70 to 72, point to a part or safety fault that a licensed gasfitter needs to check. You can safely try a reset first: turn the hot tap off and on, then the controller off and on, then the power off for 10 seconds.

  • Same-day service in most cases
  • Fixed price quoted before work starts
  • QBCC licensed plumbers and gas fitters
  • Lifetime workmanship warranty
  • $0 call-out fee
  • Family owned and operated
  • Fully insured

How to reset a Rinnai continuous flow unit

Rinnai's operation manual for its Infinity and B series continuous flow units gives three steps to clear a code. Try them in order, and stop as soon as the code clears:

  1. Turn the hot water tap off, then on again. In most cases this clears the code.
  2. Press the On/Off button on the controller off, then on again.
  3. Switch the power to the unit off, wait 10 seconds, then switch it back on. The power point is usually beside or under the unit outside.

If the same code comes straight back, don't keep resetting it. The unit is shutting down for a reason, and some of those reasons are gas or overheating faults. Write down the code and call a licensed gasfitter.

The codes you can usually fix yourself

Code 11: no ignition

This is the code we're called about most. The unit tried to light and couldn't. Rinnai's first check is the gas supply: make sure the gas is turned on at the heater and at the meter or LPG cylinder. In the hinterland and other parts of the Sunshine Coast without mains gas, the usual cause is simply an empty LPG bottle. Swap to the full bottle, or check the changeover valve has switched over, then reset.

If the gas is definitely on and code 11 keeps coming back, the problem is inside the unit: the igniter, flame rod, gas valve, gas pressure or a blocked burner. That's a job for a licensed gasfitter.

Code 12: flame failure

The unit lit, but the flame went out. Check the same things as code 11: gas on at the heater and the meter or cylinder. Rinnai also says to check the flue outlet, the vent on the front or top of the unit, for anything blocking it, such as plants or garden material growing over it. A bottle that's nearly empty can also cause code 12, because the gas pressure drops as it runs out.

Code 03: power cut during a bath fill

Some models with bath fill controllers show code 03 if the power went off while the bath was filling. Turn off all hot taps, then press the On/Off button on the controller twice.

Code 55: service reminder

On models that have it, code 55 is a reminder that a service is due, not a fault. Rinnai recommends servicing continuous flow units every 3 years. Book a service, and the reminder is reset as part of it.

Reduced water flow, no code

If hot water flow has dropped noticeably, Rinnai's manual says the inlet water filter needs cleaning, and lists it as a service call. On a new install, the filter can need cleaning a few times as debris works through the pipes.

Codes that need a licensed gasfitter

For these codes, Rinnai's advice to owners is to call for service. They involve gas, combustion, overheating or electrical safety parts. Rinnai's manual says the unit has no user-serviceable parts and must only be serviced and repaired by an authorised person, so don't take the cover off.

CodeWhat it meansWhat we check
Code 10Air supply or flue blockedFlue and air intake, fan and venting
Code 14Thermal fuse or overheat safety device has trippedOverheat switch, thermal fuse, and the heat exchanger for scale or damage
Code 16Over-temperature warningGas settings, flow sensor, thermistors, fan and heat exchanger
Code 19Electrical earth faultEarthing of the sensors, fuses and controller cable
Code 21Settings (DIP switch) faultThe unit's settings against the installation instructions
Codes 32, 33, 38, 41, 51A temperature sensor (thermistor) has failedSensor wiring and resistance, and replace the sensor
Code 52Gas valve faultGas valve wiring and solenoids, and the gas valve assembly
Code 61Combustion fan faultFan motor, wiring harness and connections
Code 65Water flow control faultThe flow control valve. If a bath fill won't stop, turn off the water
Codes 70, 71, 72Circuit board or flame sensing faultWiring harnesses, flame rod and the circuit board (PCB)
Code LCScale build-up in the heat exchanger (some models)Flushing the heat exchanger

Not every code appears on every model. Rinnai's manual notes that some codes are model-specific, so check your own manual or tell us the model when you call.

When a code means repair, and when it means replace

Most Rinnai codes are fixed with a repair: a new igniter, sensor, fan or gas valve, or a flush of the heat exchanger. Gas continuous flow units typically last 15 to 20 years, so a unit that's well inside that range is usually worth repairing.

Replacement starts to make more sense when the heat exchanger itself is damaged or leaking, the circuit board has failed on an older unit, or the same faults keep coming back. We'll give you a fixed price for both options so you can decide. Our repair or replace guide explains how to weigh it up.

Warranty: check before you book

If your unit is still under Rinnai's warranty, contact Rinnai first, because warranty repairs are usually arranged through the manufacturer. Rinnai's manual also notes that faults caused by the gas or water supply, gas or water quality, or installation or operating errors aren't covered by its warranty. An empty LPG bottle is a common example.

What to tell us when you call

  • The error code on the controller, and whether it comes back after a reset.
  • Whether you're on mains gas or LPG bottles.
  • The model, from the label on the side of the unit, if you can see it.
  • Your suburb.

We repair and replace Rinnai and other continuous flow units across the Sunshine Coast, from Pelican Waters to Noosa. See Rinnai hot water, continuous flow hot water and hot water repairs, or read why your hot water isn't working.

Common questions

What does error code 11 mean on a Rinnai?

Code 11 means the unit couldn't ignite. Check the gas is on at the heater and at the meter or LPG cylinder, and that the bottle isn't empty, then reset. If it keeps coming back, have a licensed gasfitter check the igniter, flame rod and gas valve.

What does error code 12 mean on a Rinnai?

Code 12 means the flame went out after lighting. Check the gas supply and that nothing is blocking the flue outlet. A nearly empty LPG bottle can also cause it.

How do I reset my Rinnai hot water system?

Turn the hot tap off and on. If the code stays, press the controller's On/Off button off and on. If it still stays, switch the power to the unit off for 10 seconds, then back on.

Is it safe to keep resetting a Rinnai error code?

One reset is fine. If the same code comes straight back, stop and call a licensed gasfitter, because some codes are overheating, gas or electrical safety shutdowns.

What does error code 16 mean on a Rinnai?

Code 16 is an over-temperature warning, so the unit has shut down to protect itself. It needs a licensed gasfitter to check the gas settings, sensors, fan and heat exchanger.

Why does my Rinnai show code 10?

Code 10 means the air supply or flue is blocked. Check nothing is covering the vent outside, then call for service if it continues, because the fan and venting need checking.

How often should a Rinnai continuous flow unit be serviced?

Rinnai recommends servicing its continuous flow units every 3 years. Some models show code 55 as a reminder when a service is due.

Can I fix a Rinnai error code myself?

You can check the gas supply, the LPG bottle and the flue, and do a reset. Anything beyond that involves gas and electrical parts, which must be repaired by a licensed gasfitter.

What customers say

5.0 on Google · 289 reviews

Real reviews from 289 Google reviews, copied word for word.

Reviewed by Justin Lee, QBCC licensed plumber and gasfitter

Owner of Celsius Plumbing, with more than 15 years in the trade. QBCC licence 15556725. Based on hot water jobs across the Sunshine Coast, from Pelican Waters to Noosa. Last reviewed 28 November 2026.

Sources and further reading

Last updated 28 November 2026 · Reviewed by a QBCC licensed plumber (licence 15556725)

Get a fast, free quote

Fill this in and we'll call you back with a price. Burst pipe, no hot water or a blocked drain right now? Call us instead.

Call 0434 457 046
  • Same-day service in most cases
  • Fixed price quoted before work starts
  • QBCC licensed plumbers and gas fitters
  • Lifetime workmanship warranty
  • $0 call-out fee
  • Family owned and operated
  • Fully insured
Free quote · No obligation

Get a free quote now

Tell us what's happening and we'll call you back.

  • $0 call-out
  • Fixed price
  • Lifetime warranty

We only use your details to reply about this job. Privacy policy

CallText usQuote